UL 2900- 2-1. Software Cybersecurity for Network-Connectable Products, Part 2-1: Particular Requirements for Network Connectable Components of Healthcare and Wellness Systems / Cybersécurité des logiciels pour les produits à connexion réseau, partie 2-1 : exigences particulières pour les composants à connexion réseau des systèmes de soins de santé et ….

6 CGC Fire-Resistant Assemblies Test Certification Test Conditions and Fire and sound tested assemblies listed in this Selector are based on characteristics, properties and performance Certification of materials and systems obtained under controlled test conditions as set forth in the appropriate ULC and ASTM Standards in effect at the time of test. …Nonbearing Wall Ratings — 1, 2, 3 or 4 Hr (See Items 4 & 5) 1. Floor and Ceiling Runners — (Not shown) — For use with Item 2 - Channel shaped, fabricated from min. 25 MSG corrosion-protected steel, min width to accommodate stud size, with min 1 in. long legs, attached to floor and ceiling with fasteners 24 in. OC max. 1A.

Did you know?

GCP Applied Technologies Inc., 2325 Lakeview Parkway, Suite 400, Alpharetta, GA 30009, USA GCP Canada, Inc., 294 Clements Road, West, Ajax, Ontario, Canada L1S 3C6UL certified products that comply with the code definition of “Listed,” as follows: UL Listing Mark — The traditional UL product safety Listing Mark is the most widely recognized and accepted of UL’s safety certification marks. These marks typically consist of the UL symbol, the word “Listed,” a product name and a control number.How can I search for UL certified Wall-opening Protective Materials that can be used to protect electrical boxes that create a membrane penetration in fire resistance-rated wall Designs? May 10, 2021.

UL 2900- 2-1. Software Cybersecurity for Network-Connectable Products, Part 2-1: Particular Requirements for Network Connectable Components of Healthcare and Wellness Systems / Cybersécurité des logiciels pour les produits à connexion réseau, partie 2-1 : exigences particulières pour les composants à connexion réseau des systèmes de …Detail No. Title UL Design Head of Wall Firestop System Page SW Series - Shaftwall Assemblies 09 21 16.23 1 Hour Shaftwall Partition to Steel Beam 1 Hour Shaftwall Partition Offset from Beam SW 102 SW 103 U499, W419 U499, W419 U499, W419 U499, W419 SW 104 SW 105 1 Hour Shaftwall with Deflection Track 1 Hour Shaftwall with Deflection Trackand UL Fire Ratings The following table lists the USG panels that are appropriate to use for different UL fire-resistive Designs. USG Panels USG Panels USG Panels UL Design Number UL Design Number UL Design Number G503, G531, L501, L508, N501, N502, N505, P515, P516, U026, U301, U302, U303, U304, U305, U308, U314, U321, U329, … 1. UL tests rate an entire assembly. No ceiling or suspension system product alone constitutes a fire-rated assembly. 2. You can use only the specific type, size, and minimum thickness of Fire Guard™ ceilings or suspension system identified in each assembly. 3. This table is a guide. (See UL Fire Resistance Directory for complete design details).

Each UL design outlines the required components and acceptable alternatives. The itemized product descriptions indicate if fire taping is required. Reference U305 (bearing wall) Item #2, V438 (nonbearing wall) Item #8 and W469 (bearing wall) Item #9: “Paper tape and joint compound may be omitted when gypsum panels are supplied with a square ... installation and use of UL Listed or Classified products, equipment, system, devices, and materials. Authorities Having Jurisdiction should be consulted before construction. Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements.A drywall ceiling grid offers an efficient, pre-engineered solution for installing ceilings. Among the advantages of our suspended drywall grids are their superior installation time. Additionally, our suspended gypsum ceiling options include products designed for smaller spaces. And thanks to their easy installation, the drywall suspended ... ….

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs. Ul design i504. Possible cause: Not clear ul design i504.

You have been logged out. You have been logged out due to inactivityUL/cUL I514: This testing protocol provides a two-hour fire resistance rating, using a minimum 6”, 33 mil steel stud, four layers of 5/8” type C, with resilient channel between the third and fourth layer. Detail No. Title UL Design Head of Wall Firestop System Page SW Series - Shaftwall Assemblies 09 21 16.23 1 Hour Shaftwall Partition to Steel Beam 1 Hour Shaftwall Partition Offset from Beam SW 102 SW 103 U499, W419 U499, W419 U499, W419 U499, W419 SW 104 SW 105 1 Hour Shaftwall with Deflection Track 1 Hour Shaftwall with Deflection Track

Detail No. Title UL Design Head of Wall Firestop System Page SW Series - Shaftwall Assemblies 09 21 16.23 1 Hour Shaftwall Partition to Steel Beam 1 Hour Shaftwall Partition Offset from Beam SW 102 SW 103 U499, W419 U499, W419 U499, W419 U499, W419 SW 104 SW 105 1 Hour Shaftwall with Deflection Track 1 Hour Shaftwall with Deflection TrackBuilding Products and Systems. You can rely on UL Solutions' safety science leadership to help solve your safety, quality assurance and compliance challenges. Our comprehensive inspection, validation and certification services for the building and construction products industry help you bring products and systems to market quickly and cost ...

spanish cobras leaders flint Contact our technical services department at. 1-888-834-2371, or email [email protected]. For additional information about these or other Thermafiber products contact us at 1-888-834-2371 or visit our website www.thermafiber.com. chatarbuteskipthegames altoona pa 1. UL tests rate an entire assembly. No ceiling or suspension system product alone constitutes a fire-rated assembly. 2. You can use only the specific type, size, and minimum thickness of Fire Guard™ ceilings or suspension system identified in each assembly. 3. This table is a guide. (See UL Fire Resistance Directory for complete design details).Submittal Builder. Find the documents you need to build with products you trust. Get Started. Discover our tools & resources including drawings, specifications, continuing education, and more with the National Gypsum® Design Center. Click here. tmcc lienholder Oct 9, 2023 · For shafts that do not extend to the underside of the roof sheathing, a horizontal membrane is required with the same fire rating as the shaft enclosure. Reference pages 67 and 68 of The Wood Book for 1-hour membranes using UL design I504 and pages 75 and 79 for 2-hour membranes with UL design I516. Are penetrations permitted in shaft enclosures? taylor swift metlife ticketmasterthat's right lyricsrain sounds black screen 2 hours USE IN UL CLASSIFIED SYSTEMS (GA-605) Rev. June 13, 2014 The Fire Resistance Directory published by Underwriters Laboratories Inc. lists gypsum panel products that are classified for fire resistance under category “Gypsum Board (CKNX).” Each UL Design lists the specific manufacturers and products that are suitable for use in the design. texas lotto texas two step One-Hour Wall Membrane (Based on UL Design U 301) The membrane consists of two layers of 5/8” (15.9 mm) type X gypsum board directly applied to framing or furring. The base layer of gypsum board is applied either parallel or at right angles to wall or partition framing 16” (406 mm) o.c. and attached with 1” (25 mm) Type S or S-12 drywall ...Design Thicknessb Minimum Thickness Style in. mils in. mils ga. CH, ES 0.0188 18 0.0179 18 25 JR 0.0239 22 0.0227 23 24 CH, ES, JR, JS 0.0359 33 0.0341 34 20 Structural Properties–Steel Framing Components Component Product Average Weight Area Ix Sxc Allowance Design tsccard.accountonline com activatecommercial.century 21reshonda landfair where is she now URGENT! We have installed a ceiling with ul i504 but have areas of Pipe penetrations. What do we do here for sealing? fire caulk? See attached detail for clarification.